** Please copy both files into the Upgrade file folder
** If the version of APP2_DSO_TC4_xxx.bin is the same as before the update, you can upload only APP1_DSO_TC4_xxx.bin
————————————————————————————————————————————————————————
Upgrade log:
----------20251029----------
APP1_DSO-TC4_V0.0.7_251029
  1. Fixed a bug where some units might not display charging status when powered off and charging.

----------20251009----------
APP1_DSO-TC4_V0.0.6_251009
  1. Fixed the issue where voltage measurement in the toolbox displayed incorrectly.

----------20250321----------
APP1_DSO-TC4_V0.0.3_250228
APP2_DSO_TC4_V1.0.9_250321
  1. Fixed the measurement error problem of 5.1K to 20K
  2. Fixed the problem that the resistance of 20K to 999K is displayed as M units

----------202250228----------
APP1_DSO-TC4_V0.0.3_250228
  1. When measuring two diodes in the transistor, the picture display is wrong and the parameters are displayed redundantly

----------20250221----------
APP1_DSO-TC4_V0.0.2_250221
APP2_DSO_TC4_V1.0.7_20250221
  1. Fix the issue where only single measurement is possible and requires a restart for a new measurement.
  2. Fix the diode measurement direction issue.
  3. Fix the incorrect display of maximum, minimum, and peak-to-peak values in the oscilloscope.
  4. Fix the issue where transistor measurements display two diodes too closely.
  5. Modify other known issues.